仪器分类
Gel Permeation Chromatography Instrument_凝胶渗透色谱仪器
Gel Permeation Chromatography Instrument_凝胶渗透色谱仪器
仪器编号
2024032900350
SN序列号
1260 Infinity II
生产厂家
Agilent
型号
DEAEQ68009/DEAED45953/DEACX39086
制造国家
USA
分类号
放置地点
SA Building SA534K
购置日期
2023-11-01
入网日期
2024-05-28

主要规格及技术指标

1260 Infinity II Isocratic Pump, maximum pressure 600bar. Includes
isocratic pump, column, connecting capillaries, solvent cabinet,
solvent bottles and CAN cable.
Mobile Phase: The solvent should be of HPLC-grade purity and needs to be filtered before use.
Pump: It is a binary pump, the 1260 Pump with model G7111. The flow rate setting range is 0 - 10 ml/min, and the pressure limit is 0 - 200 bar.
Pressure Limit: The upper and lower pressure limits should be set reasonably. The upper pressure limit (Max) should not exceed the maximum pressure that the column and the instrument can withstand. Generally, it should be set about 20 bar higher than the normal analysis pressure. The lower pressure limit (Min) is usually set about 20 bar lower than the normal analysis pressure.
Autosampler: There are two sample trays, P1 and P2. The input format is, for example, P1-A1, which represents position A1 in the front sample tray of the first-layer drawer, and the rear sample tray of the first layer is P2. The model is G7129A 1260 Vialsampler, with an injection volume range of 0 - 100 microliters.
Column Oven: It is temperature-controllable within the range of 4 - 85℃. The model is G7116A 1260MCT.
Detector Parameters
There are two detectors. One is a UV detector with the model 1260VWD G7114A. The wavelength setting range is 190 - 600 nm.
The other is an RID (Refractive Index Detector) with the model 1260RID G7162A. This detector can only be used for isocratic elution. It is recommended to set the detector temperature at least 5°C higher than the room temperature.

主要功能及特色

Accurate molecular weight - it can provide perfect results regarding the true polymer's molecular weight
Features:
Accuracy — Delivers reproducible and consistent molecular weight distributions.
High Performance — Features a rapid and stable system that significantly enhances sample throughput.
Versatility — Enables the operation of both GPC/SEC and LC on the same system.
Simplified Data Analysis — Controls the instrument, acquires data, and analyzes polymers through three straightforward steps.
Advanced Detector Integration — Allows for the easy addition of light scattering and viscosity detectors at any time to obtain more detailed information about polymer molecular weight and distribution.
Reduced Solvent Costs — Automatically recycles solvent when polymer peaks are not being eluted.
Unattended Operation — Achieves full workflow automation using the 1260 Infinity II vial sampler.
Exceptional Precision — System stability facilitates easier peak integration and delivers excellent reproducibility.

主要附件及配置

Autosampler G7129A;
1260 Infinity II Variable Wavelength Detector G7114A;
1260 Infinity II Refractive Index detector G7162A